Index of /VBAS/CCDOPS

      Name                    Last modified       Size  Description

[DIR] Parent Directory 17-May-2002 16:41 - [   ] C8SATURN.ST5 17-May-2002 16:40 25k [   ] CCDOPS.CFG 17-May-2002 16:40 2k [   ] CCDOPS.EXE 17-May-2002 16:40 528k [   ] CGA.BGI 17-May-2002 16:40 6k [   ] DEMO.SLD 17-May-2002 16:40 1k [   ] EGACOLOR.TBL 17-May-2002 16:40 1k [   ] EGAMONO.TBL 17-May-2002 16:40 1k [   ] EGATEMP.TBL 17-May-2002 16:40 1k [   ] EGAVGA.BGI 17-May-2002 16:40 5k [   ] F3DUMB.STX 17-May-2002 16:40 35k [   ] F3N6946.STX 17-May-2002 16:40 37k [   ] F3TRIFID.STX 17-May-2002 16:40 36k [   ] FILTER.CFG 17-May-2002 16:40 1k [   ] HORSE-SB.ST6 17-May-2002 16:40 131k [   ] JUPITER.ST5 17-May-2002 16:40 30k [   ] M1.ST5 17-May-2002 16:40 88k [   ] M27F.ST7 17-May-2002 16:40 320k [   ] M51.ST5 17-May-2002 16:40 108k [   ] M57RGB.STX 17-May-2002 16:40 21k [   ] MCGABLUE.TBL 17-May-2002 16:40 1k [   ] MCGACOL.TBL 17-May-2002 16:40 1k [   ] MCGATEMP.TBL 17-May-2002 16:40 2k [   ] PATH.CFG 17-May-2002 16:40 1k [   ] SVGA256.BGI 17-May-2002 16:40 9k [   ] VGA256.BGI 17-May-2002 16:40 3k [   ] VGACOLOR.TBL 17-May-2002 16:40 1k [   ] VGATEMP.TBL 17-May-2002 16:40 1k [   ] XVGACOL.TBL 17-May-2002 16:40 1k [   ] XVGATEMP.TBL 17-May-2002 16:40 2k

                       Santa Barbara Instrument Group
                             Applications Note
                            CCDOPS Version 3.6
                              March 4, 1997

This Application Notes describes the changes made to CCDOPS since version
3.5

Additions made to CCDOPS
* Added support for the VESA 1280x1024 by 256 color mode for photo mode.
* In guiding commands the software now forces the centroid of the guide star
  to the center of the pixel for maximum S/N
* The adaptive dark subtract routine now makes sure there is enough image
  statistics for the adaptive algorithm.  Otherwise default coefficient
  of 1 is used.
* Added a Spot focus mode to the ST-7, ST-8 and PixCel255 that follows
  the brightest spot in the image around.  It takes a full frame image in
  the low res mode to find the bright spot and then tracks that spot around.
  If you want to reacquire the bright spot within Focus mode reenter the
  Spot mode by hitting the 'B' key or with the pull-down menu.
* Added a large version of the peak readout to the lower-left corner of
  the Focus mode that makes reading this from across the room easier.
* Increased the maximum size of a HP laser printed image to 8 inches.
  In the older software ST-7 images would print at 2.5 inch width and
  now they print at 7.5 inch width.
* Added a Turbo update mode to the Focus command for the ST-7 and ST-8
  that allows shorter image times and faster throughput by just leaving
  the shutter open.  You will notice steaking of bright objects with short
  exposures when using this mode since these CCDs are not frame transfer
  CCDS.
* Reduced the size of the tracking image in the ST-7/8 to exclude hot
  pixels that showed up at the bottom of some units making the
  Tracking Calibrate routine require brighter stars.
* Allow up to 9999 images in auto grab.
* An Auto Bias feature has been applied to ST-7/8 Imaging CCD images
  such that short dark images will now show around 100 counts.
  Also, the Display Parameters dialog has been updated to show whether
  Auto Bias Level was used to capture ST-7/8 images by the addition
  of the ABL field in the Readout State data.
* We added an option titled "Non-ABG Streak Removal" to the ST-7/8
  Camera Setup Command.  Users of non-ABG protected versions of these
  cameras should enable this option to prevent horizontal streaking of
  bloomed stars.  This is only active in the Medium and Low Resolution
  modes where the on-chip binning causes this effect.  This slows down
  the readout in these binned modes but removes the unsightly effect.
  Note that this is applied in the Focus mode so as to not slow down
  focusing unless you have enabled the Auto Grab mode of the Focus command.
     Users with ABG protecte versions of these cameras should leave this    
  option disabled.
* We removed the artifical saturation limit of 16,384 counts when the
  ST-7/8 were used in the high resolution mode.  Now rather than limiting
  the A/D at 16K we let the CCD's saturation limit the readout.  This allows
  users of the non-ABG versions of these cameras to realize the higher
  full-well capacity of those cameras.

Bug Fixes made to CCDOPS
* Fixed a bug in the PARDRV driver that could cause ST-7/8 cameras
  to have a slight horizontal streaking in low level light frames on
  fast computers
* Fixed a bug that could cause Auto-dark subtracted images
  to be corrupted when running under Windows and when
  extended memory was low
* Fixed a memory leak that caused the software to hang on exiting to DOS
  when used with an ST-7/8 and the active CCD was changed.
* Fixed a bug in the Dark Subtract command in the Utility menu that would
  clip ST-7/ST-8 high-res pixels to 16383 counts.
* Fixed a bug in the VESA driver that caused the mouse cursor to show
  stripes on some VESA displays and to move in increments of
  4 pixels.
* Fixed a bug in the VESA driver that would leave images of the selection
  box behind as it was moved on some VESA displays.
* Fixed a bug where taking an image thru midnight would report much time
  left in the exposure.
* Fixed a bug in the Zoom 4X and Replicate commands where images that
  had been previously Enlarged and then Zoomed would get corrupted.
* Fixed a bug that when a Color Grab sequence was taken with the Track
  and Accumulate command the filter wheel would always try to use the